MULTI FUNCTION TESTER KEW 6516BT

Availability : in stock
Category:
Share:

DISPLAY                Color LCD 3.5 inches dot matrix.
ATT                        Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOP                      ・High test current range of 2Ω with 0.001Ω resolution.
・Zs Limit compares the values required by Electrical Installations Standard with
measured results.
RCD                        ・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
・Single and Auto test, Ramp test and Contact voltage.
EARTH                    ・Earth resistance test 2 and 3 wires with all accessories included.
INSULATION         ・Resistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITY         ・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATION ・On 3-phase lines with clear indication of the sequence on the display.
VOLTS                    ・TRMS Voltage measurements 2-600V, Mains Frequency.
HELP                      ・Display shows how to connect the instrument according to the function selected.
SPD                        ・Surge Protection Device test, for SPD that uses varistor.
PAT                        ・Portable Appliance Tester function, for Insulation and Protective conductor resistance test
Bluetooth               ・Communication by “KEW CONNECT”
SAFETY                  ・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10.

Insulation resistance SPD(Varistor)
Test
voltage
100V 250V 500V 1000V Max.1000V
Measuring
ranges
2.000/20.00/200.0MΩ
(Auto-ranging)
20.00/200.0/1000MΩ
(Auto-ranging)
20.00/200.0/2000MΩ
(Auto-ranging)
0-1000V
(goes up by 1V)
Accuracy ±2%rdg±6dgt
(2.000/20.00MΩ)
±5%rdg±6dgt
(200.0MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(1000MΩ)
±2%rdg±6dgt
(20.00/200.0MΩ)
±5%rdg±6dgt
(2000MΩ)
±5%rdg±5dgt
Rated
current
1.0-1.2mA
@0.1MΩ
1.0-1.2mA
@0.25MΩ
1.0-1.2mA
@0.5MΩ
1.0-1.2mA
@1MΩ
Short circuit current 1.5mA max
Loop impedance
Function LOOP ATT LOOP HIGH
L-PE/L-N
(3wire)
L-PE(2wire) L-PE
(0.01ΩRes)
L-PE
(0.001ΩRes)
High test
current(25A)
L-N/L-L
Rated
voltage
100-260V
(50/60Hz)
48-260V
(50/60Hz)
48-260V
(50/60Hz)
100-260V
(50/60Hz)
48-500V
(50/60Hz)
Impedance
range
20.00/200.0/2000Ω
(Auto-ranging)
20.00/200.0/
2000Ω
(Auto-ranging)
2.000Ω 20.00Ω
Accuracy ±3%rdg±6dgt ±3%rdg±10dgt ±3%rdg±4dgt ±3%rdg±25mΩ ±3%rdg±4dgt
Nominal
test
current at
0Ω external
loop:
Magnitude/
Duration at 230V
L-N:6A/60ms
N-PE:10mA
L-PE:15mA 20Ω:
6A/20ms
200Ω:
0.5A/20ms
2000Ω:
15mA/500ms
25A/20ms 6A/20ms
PSC/PFC
Range 2000A/20kA
(L-N(PSC)/
L-PE(PFC))
2000A/20kA
(PFC)
2000A/20kA
(PFC)
2000A/50kA
(PFC)
2000A/20kA
(PSC)
Accuracy PSC/PFC accuracy is derived from measured loop impedance specification
and measured voltage specification
RCD
Rated voltage 100-260V(50/60Hz)
Function x1/2, x1,x5,Ramp,Auto,Uc
6/10/30/100/300/500/1000mA/variable
RCD type AC(G/S) A(G/S) F(G/S) B(G/S) EV
Trip
current
setting
x1/2,
x1,Uc
10/30/100/300/
500/1000mA(G)
10/30/100/
300/500(S)
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA(x1 only)
x5 10/30/100mA 10/30/100mA 10/30/100mA 10/30mA
Ramp 10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300/500mA
10/30/100/
300mA
6mA
Accuracy
Trip
current
x1/2 -8% – -2% -10% – 0% -10% – 0% -10% – 0%
x1 +2% – +8% 0% – +10% 0% – +10% 0% – +10% 0% – +10%
x5 +2% – +8% 0% – +10% 0% – +10% 0% – +10%
Ramp -4% – +4% -10% – +10% -10% – +10% -10% – +10% -10% – +10%
Trip
time
x1/2 2000ms(G/S):±1%rdg±2ms
x1 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms 10.5s:±1%±2㎳
x5 410ms(G/S):±1%rdg±2ms
Continuity
Range 20.00/200.0/2000Ω (Auto-ranging)
Open circuit voltage(DC) 7-14V
Measuring current 200mA >200mA or more(2Ω or less)
15mA 15mA±3mA(short-circuit)
Accuracy ±2%rdg±8dgt
Volts
Range 300.0/600V(Auto-ranging)
Measuring ranges Volts 2-600V
Frequency 45-65Hz
Accuracy Volts ±2%rdg±4dgt
Frequency ±0.5%rdg±2dgt
Phase Rotation
Rated voltage 48-600V(50/60Hz)
Remarks Remarks Correct phase sequence: are displayed “1.2.3” and mark
Reversed phase sequence: are displayed “3.2.1” and mark
Earth
Range 20.00/200.0/2000Ω(Auto-ranging)
Accuracy ±2%rdg±0.08Ω(20.00Ω)
±2%rdg±3dgt(200.0/2000Ω)
Applicable standards IEC 61010-1 CAT IV 300V ,CAT III 600 V Pollution degree 2
IEC 61010-2-034
IEC 61557-1,2,3,4,5,6,7,10
IEC 60529(IP40)
IEC 61326(EMC)
Power source LR6 (AA) (1.5V) ×8
Communication interface USB, Bluetooth® Ver. 5.0
Dimensions / Weight 136(L) × 235(W) × 114(D) mm / Approx. 1350g (including batteries)
Included Accessories Main test lead※1
7281 (Test leads with remote control switch)
7246 (Distribution board test lead)
7228A (Earth resistance test leads)
8041 (Auxiliary earth spikes[2 spikes/1 set])
9084 (Soft case)
9142 (Carrying case)
9151 (Shoulder strap)
9199 (Shoulder pad)
LR6(AA) × 8, Instruction manual, Calibration certificate
Optional Accessories 8212-USB (USB adaptor with “KEW Report(Software)”)
8259 (Adapter for measurement terminal)
7272 (Precision measurement Cord set)
8017A (Extension prod long)
8602 (EVSE ADAPTER)

There are no reviews yet.

Be the first to review “MULTI FUNCTION TESTER KEW 6516BT”

Your email address will not be published. Required fields are marked *