Showing 1–9 of 13 results

PHASE INDICATOR KEW 8031

Simple operation and ruggedness.
Check of open phase and phase sequence are possible in one unit.

Long selling models were renewed with the design and the measurement category!

・Two Functions in One Unit
Presence of open phase can be checked by the lamps, and the phase
sequence can be indicated by the rotating disk.

・ High Reliability
measuring range for 3-phase installations from 110V to 600V.
Sealed against dust ensures the trouble-free performance.

Quick View

SIGNAL SOURCE FOR INTELLIGENT SOCKET TESTER KEW 8343

When used in combination with the Intelligent Socket Tester (KEW 4506), the capabilities of the Intelligent Socket Tester can be greatly expanded.

*KEW 8343 is cannot be measured alone.

Quick View

POWER METER KEW 6305

• Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
• Voltage, Current, Power Factor and Frequency measurements
• Power analysis (Active, Apparent and Reactive power)
• Energy analysis (Active, Apparent and Reactive power)
• Active power accuracy: ±0.3%rdg±0.2%f.s.
• Automatic wiring check function to prevent incorrect connections
• Large memory capability (2GB) using built-in SD card interface
• Real time & remote measurements using Android application
• synchronous measurements between two units of KEW 6305
• Wide selection of clamp sensors allow measurements from 0.1A to 3000A
• The instrument automatically recognizes what kind of clamp sensor is connected to it
• Windows software for data analysis and setting via USB port or Bluetooth

Quick View

MULTI FUNCTION TESTER KEW 6516BT

DISPLAY                Color LCD 3.5 inches dot matrix.
ATT                        Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOP                      ・High test current range of 2Ω with 0.001Ω resolution.
・Zs Limit compares the values required by Electrical Installations Standard with
measured results.
RCD                        ・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
・Single and Auto test, Ramp test and Contact voltage.
EARTH                    ・Earth resistance test 2 and 3 wires with all accessories included.
INSULATION         ・Resistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITY         ・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATION ・On 3-phase lines with clear indication of the sequence on the display.
VOLTS                    ・TRMS Voltage measurements 2-600V, Mains Frequency.
HELP                      ・Display shows how to connect the instrument according to the function selected.
SPD                        ・Surge Protection Device test, for SPD that uses varistor.
PAT                        ・Portable Appliance Tester function, for Insulation and Protective conductor resistance test
Bluetooth               ・Communication by “KEW CONNECT”
SAFETY                  ・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10.

Quick View

FLEXIBLE CLAMP SENSOR KEW 8135

Flexible Clamp Sensor that is very useful for measuring low current around 5A

・Conductor size max.φ75mm
・Can measure AC current up to 50A
・Flexible and light weight by the air core coil used at the sensor part
・Designed to meet the international safety standard IEC 61010-1
CAT IV 300V, CAT III 600V

Quick View

VOLTAGE TESTER KT 171

• AC and DC voltage tests up to 690V with LEDs and LCD
• Comply with the latest standards IEC 61243 and IEC 61010
• Novel design
Large and bright LEDs: Values are visible in the dark place
Ergonomic design fits in the hand
• Two functions are available in one model
“Measurement without battery” and “Self Test (all LED on)”
• Test leads withstand harsh environments at low temperature
• Penlight (white LED)
• Auto-power ON/OFF
• Audible indication
• Variable test tips, φ2mm or φ4mm
• Probe protection cover can store the attachment of caps
• IP65 (IEC 60529)

Quick View

RCD TESTER KEW 5410

• Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at
× 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
• Measurement of trip out current
Measuring trip out current by varying current automatically.
• Remote Test
Enabling a user to hold the Test Leads with his both hands
by locking the Test Button. Measurement will automatically
start when the main voltage is detected.
• Voltage Measurement
Carrying out a constant measurement of voltage in the
stand-by mode at each Range.
• Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or
Protective conductors during RCD test – when applying
test currents – at measurement using EARTH in order to
prevent electrical shocks caused by the damaged earth.
Measurement will be ceased at AC50V or more.
• Dust- and Water-proof
Dust- and Water-proof construction
(designed to IEC 60529 IP54).
• Backlight
Facilitating working at dimly illuminated locations.

Quick View

MULTI FUNCTION TESTER KEW 6516BT

DISPLAY                Color LCD 3.5 inches dot matrix.
ATT                        Anti-Trip Technology (with 2 & 3 wire) for no trip LOOP L-PE testing on all RCDs.
With 2 wire only, very useful in case of no Neutral (i.e. 3-phase motor lines).
LOOP                      ・High test current range of 2Ω with 0.001Ω resolution.
・Zs Limit compares the values required by Electrical Installations Standard with
measured results.
RCD                        ・Type AC, A, F, B(General & Selective), EV and Variable RCDs.
・Single and Auto test, Ramp test and Contact voltage.
EARTH                    ・Earth resistance test 2 and 3 wires with all accessories included.
INSULATION         ・Resistance test 100, 250, 500 & 1000V with auto discharge voltage.
CONTINUITY         ・Continuity test at 200mA or 15mA with selectable buzzer for fast judgment.
PHASE ROTATION ・On 3-phase lines with clear indication of the sequence on the display.
VOLTS                    ・TRMS Voltage measurements 2-600V, Mains Frequency.
HELP                      ・Display shows how to connect the instrument according to the function selected.
SPD                        ・Surge Protection Device test, for SPD that uses varistor.
PAT                        ・Portable Appliance Tester function, for Insulation and Protective conductor resistance test
Bluetooth               ・Communication by “KEW CONNECT”
SAFETY                  ・IEC 61010-1 CAT IV 300 V, CAT III 600 V. IEC 61557-1,2,3,4,5,6,7,10.

Quick View

EARTH TESTER KEW 4105DLBT-H

IP67 Dust & Water-Proof rugged EARTH TESTER
Bluetooth enabled for data transfer
Hard Case Model

・3pole and 2pole Earth Resistance measurement (0.01Ω‐2000Ω)
・Waterproof design
・Bluetooth® enabled for data transfer
・Noise rejection up to 25V rms allows accurate testing in noisy environments
・Rotary Switch makes the user interface very intuitive
・Large LCD Display with Backlight
・LED to monitor correct / non correct auxiliary earth spike resistance
・Earth Voltage Measurement (AC / DC 0‐300V)

Quick View